Design
Modular room design based on the product, temperature, capacity, and available space.

Modular Cold Room Solutions
Modular Cold Room Solutions for Flexible Temperature Controlled Storage
Uniref designs, supplies, installs, and commissions customized modular cold rooms for temperature sensitive products and industrial applications across India. Each room is planned around the product, required temperature, storage capacity, available space, refrigeration load, and operating requirements.
Engineering coordination from Jaipur. Call +91 7222 001 000.
Modular room design based on the product, temperature, capacity, and available space.
Insulated panels, doors, refrigeration equipment, controls, and associated components.
Modular cold room construction, refrigeration equipment, electrical controls, and related systems installed at site.
Testing, system commissioning, operating checks, and handover after installation.
Project record
20+ years of experience, 2,500+ projects completed, offices in Jaipur, Chennai, Delhi and Indore, 40+ service locations, 4+ assembly facilities.
Businesses across food, pharmaceutical, hospitality, agriculture, distribution, and other temperature sensitive applications use modular cold rooms for controlled storage and product handling.





How the room is planned
A modular cold room needs to fit both the storage requirement and the available site. Room dimensions, insulated panels, doors, refrigeration equipment, flooring, airflow, controls, and product movement are considered together to establish the appropriate configuration.
Uniref develops customized modular cold storage solutions around the product and operating process. Capacity is confirmed from the product, packaging, stacking, aisles, daily movement, and available space rather than using a standard room size.

The room dimensions, panel configuration, doors, refrigeration equipment, and internal layout are planned according to the application.
Temperature control is configured around the specified product requirement and selected refrigeration system.
Humidity requirements are considered where moisture conditions are important to the product or storage process.
Room dimensions, product placement, aisles, door locations, and loading patterns are considered to make effective use of available space.
Insulation, refrigeration equipment, evaporator selection, doors, airflow, and controls are considered together during system design.
Temperature monitoring, alarms, data logging, controls, and selected remote monitoring functions can be incorporated according to the project requirement.
Room types
Modular construction can be adapted to different temperature ranges, products, room sizes, and operating requirements. Uniref develops the insulated enclosure and refrigeration system according to the actual application.

Around 0°C to 8°C
Around 0°C to 8°C
Modular chilled cold rooms can be designed for products commonly held around 0°C to 8°C, subject to the specific product and operating requirement.

Near minus 18°C or lower
Near minus 18°C or lower
Modular frozen cold rooms can be designed for low temperature storage, commonly near minus 18°C or lower, depending on the product and required operating conditions.

Separate storage conditions
Separate storage conditions
Separate temperature controlled areas can be incorporated where different products require different storage conditions within the same facility.

Around 2°C to 8°C
Around 2°C to 8°C
Pharmaceutical applications can require controlled conditions around 2°C to 8°C for suitable products, with monitoring and alarm functions configured according to the requirement.

Staff and equipment access
Staff and equipment access
Modular walk in rooms provide accessible storage areas where personnel and handling equipment need to enter for loading, unloading, and product movement.

Hotels and food service
Hotels and food service
Commercial modular cold rooms can support hotels, restaurants, food service operations, distribution facilities, and other businesses requiring controlled storage.

Larger storage requirements
Larger storage requirements
Industrial modular cold rooms can be configured around larger storage requirements, dedicated refrigeration equipment, product movement, and facility infrastructure.

Part of a larger store
Part of a larger store
Modular rooms can form part of broader cold storage warehouse solutions where additional temperature controlled storage areas are required.
Share your product, required temperature, approximate capacity, available space, and project location with our engineering team.
Design inputs
The Product, Room, and Site Shape the Design. A modular cold room should be designed around the product and the way the facility will operate. Uniref reviews the product, temperature, capacity, room dimensions, storage arrangement, site conditions, utilities, and daily movement before finalizing the system.
What will be stored?
The product determines the required temperature, humidity, airflow, insulation, refrigeration capacity, and storage arrangement.
Capacity in MT, pallets, or volume
The required quantity helps establish room dimensions, storage layout, refrigeration load, and available operating space.
Temperature when goods enter
Incoming product temperature affects refrigeration demand and helps determine the required pull down and holding conditions.
Quantity entering per day
Daily product movement affects refrigeration load, door openings, loading frequency, and room utilization.
Operating range
The specified temperature range provides the basis for refrigeration equipment, insulation, controls, and monitoring.
Required relative humidity
Humidity requirements are reviewed according to the stored product and intended storage process.
Available space
Available floor area, ceiling height, access, and surrounding infrastructure influence room dimensions and equipment placement.
Door openings and traffic
Door opening frequency and product movement affect thermal load and influence door selection, airflow, and operating conditions.
Local Indian climate
Ambient conditions at the project location affect refrigeration load and selection of the refrigeration system.
Power availability
Available electrical supply and site utilities are reviewed before equipment and controls are finalized.
Backup, if applicable
Where backup power or other continuity provisions are required, these can be considered as part of the overall project requirement.
Share your product, required temperature, approximate capacity, available space, and project location with our engineering team.
Operating cost
Engineering the Complete System. Operating efficiency depends on the combined performance of insulation, refrigeration equipment, doors, airflow, controls, lighting, and defrost. Uniref considers these elements together when developing the modular cold room design.

Select a measure to see how it is built
Visibility
Monitor Room Conditions and Refrigeration Equipment. A modular cold room can incorporate monitoring functions that provide visibility into temperature, humidity, equipment status, and selected operating parameters. The monitoring arrangement is configured according to the number of rooms, refrigeration equipment, product requirements, and level of control required. Sample figures shown on a diagram are illustrative. A live monitoring panel shows the actual rooms, equipment, and parameters configured for that project.
Digital temperature monitoring provides visibility into the operating temperature of individual rooms and selected equipment.
Humidity monitoring can be included where relative humidity is important to the stored product or operating process.
Alarm systems can identify selected high temperature, low temperature, equipment, electrical, and system conditions that require operator attention.
Data logging can record selected temperature, humidity, equipment status, and other operating parameters for review.
Remote monitoring can provide access to selected room and refrigeration information away from the local control panel when the project requires it.
The monitoring interface can display selected compressor, condensing unit, evaporator, fan, control, and other equipment status information.
High and low temperature alerts can notify operators when the room moves outside its defined operating range.
Multiple modular rooms and selected refrigeration equipment can be brought into a centralized control environment according to the project requirement.
IoT integration can be considered when the operation needs additional connectivity, remote data access, or integration with other systems.
Illustrative status
Room
4.2°C
Humidity
76%
Compressor
Running
Defrost
Idle
Sample trend for a holding period. Not a live site reading.
Discuss your refrigeration equipment, temperature requirements, monitoring needs, and operating conditions with our engineering team.
Working with Uniref
Engineering, Supply, Installation, and Support. A modular cold room requires coordination across the insulated enclosure, refrigeration plant, doors, flooring, controls, monitoring, electrical systems, and storage requirements. Uniref manages these elements around the application and site conditions.
How It Is Designed
The modular room is developed around the product, temperature, capacity, loading pattern, available space, refrigeration load, and operating conditions.
How It Is Designed
Insulation, refrigeration equipment, evaporators, doors, airflow, controls, lighting, and defrost are considered together during system design.
How It Is Delivered
The project scope can include requirement analysis, site assessment, heat load calculation, design, equipment selection, manufacturing and supply, installation, testing, commissioning, training, and handover.
How It Is Delivered
Refrigeration equipment and associated components are selected according to the calculated load, operating conditions, and project requirements.
How It Stays Running
Uniref supports modular cold room project requirements across India, with engineering coordination from Jaipur and support through its operating network.
How It Stays Running
Post installation support can include preventive maintenance, AMC, breakdown support, spare parts, system inspection, refrigeration repairs, performance optimization, and selected upgrades.
Uniref provides customized modular cold storage solutions for businesses that require controlled temperature storage and coordinated refrigeration engineering.
What you store
The Product Inside the Room Determines the Design. The correct modular cold room starts with the product inside it, not simply the industry name. Product temperature, incoming condition, packaging, quantity, storage duration, humidity, airflow, and daily movement all influence the room and refrigeration design.

Many fruits are commonly held around 0°C to 4°C, although the suitable range depends on the specific fruit, condition, and storage requirement.

Many vegetables are commonly stored around 0°C to 4°C, but temperature and humidity requirements vary by commodity.

Dairy products are often stored around 2°C to 4°C, subject to the specific product and handling requirements.

Ice cream requires frozen storage, commonly near minus 18°C or lower, depending on the product and required storage conditions.

Fresh meat is commonly held around 0°C to 4°C, while frozen meat requires substantially lower temperatures according to the product requirement.

Fresh poultry is commonly held around 0°C to 4°C, with the exact requirement determined by the product and operational process.

Seafood can require chilled or frozen storage depending on the product, handling process, packaging, and intended storage duration.

Frozen food is commonly stored near minus 18°C or lower. The refrigeration system and modular room construction are selected according to the product and operating conditions.

Many medicines require controlled storage around 2°C to 8°C, but the required range must be confirmed from the specific product requirements.

Vaccines can commonly require storage around 2°C to 8°C, subject to the product specification and applicable handling requirements.

Seed storage requirements vary by seed type, moisture condition, temperature, and intended storage period. The modular room is designed around the specified product conditions.

Flowers are typically stored around 1°C to 5°C, subject to the specific flower type, packaging, humidity requirement, and storage process.
These temperature ranges are typical guidance only. Temperature controlled storage solutions should always be designed from the actual product specification and operating conditions.
Share your product type, required temperature, approximate capacity, storage duration, available space, and project location with our engineering team.
Documentation
Uniref has quality documentation on file for cold rooms, heat exchangers, condensing units, and their parts, including ISO 9001:2015, certificate QMS/23M0934, GMP, certificate GMP/23M0935, and CE compliance with the Machinery Directive 2006/42/EC, certificate CE/23M0936. These documents were first registered on 7 April 2023, with recertification due on 6 April 2026. Ask the Uniref team for the current documents applicable to your project.

Uniref supports modular cold room projects as a cold storage manufacturer in India, coordinating engineering, supply, installation, and commissioning.
Materials and internal surfaces are selected according to the application, product handling requirements, hygiene conditions, and intended operating environment.
Panels, insulation, doors, flooring, and refrigeration equipment are considered together to support the specified temperature conditions.
Electrical controls, wiring, protection devices, and associated equipment are selected and installed according to the refrigeration system and project requirements.
Selected refrigeration, electrical, and cold room components are assessed according to the system requirements before being incorporated into the project.
Modular cold room construction is planned with consideration for cleaning, product handling, internal access, joints, surfaces, and the operating environment.
Safety functions and control arrangements are incorporated according to the refrigeration system, electrical equipment, cold room operation, and project requirements.

After a service visit
2.1°C
A controller check on an installed room. The figure is illustrative, not a live site reading.
After handover
Support After Your Modular Cold Room Is Commissioned. A modular cold room requires ongoing attention to refrigeration equipment, panels, doors, controls, sensors, and operating conditions. Uniref provides post installation support according to the installed system and facility requirements.
01 / 08
Service log
Planned maintenance can include inspection of refrigeration equipment, electrical controls, sensors, doors, insulation, monitoring systems, and other relevant components.
Questions
A modular cold room is a temperature controlled storage room assembled from insulated panels, doors, refrigeration equipment, flooring, controls, and related components. Its dimensions and configuration can be developed around the available space, product, required temperature, storage capacity, and operating process. Modular construction can be used for chilled, frozen, pharmaceutical, commercial, and industrial applications, with the refrigeration system selected according to the actual heat load and temperature requirement.
Tell Us What You Need to Store
Share your storage product, required temperature, approximate capacity, available space, and project location so our engineering team can understand the application and define the next steps.
Tell Us What You Need to Store
Share your storage product, required temperature, approximate capacity, available space, and project location so our engineering team can understand the application and define the next steps.